Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
Add more filters










Publication year range
1.
J Environ Manage ; 352: 119985, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38184870

ABSTRACT

Flooding is expected to increase due to climate change, urbanisation, and land use change. To address this issue, Nature-Based Solutions (NBSs) are often adopted as innovative and sustainable flood risk management methods. Besides the flood risk reduction benefits, NBSs offer co-benefits for the environment and society. However, these co-benefits are rarely considered in flood risk management due to the inherent complexities of incorporating them into economic assessments. This research addresses this gap by developing a comprehensive methodology that integrates the monetary analysis of co-benefits with flood risk reduction in economic assessments. In doing so, it aspires to provide a more holistic view of the impact of NBS in flood risk management. The assessment employs a framework based on life-cycle cost-benefit analysis, offering a systematic and transparent assessment of both costs and benefits over time supported by key indicators like net present value and benefit cost ratio. The methodology has been applied to the Tamnava basin in Serbia, where significant flooding occurred in 2014 and 2020. The methodology offers valuable insights for practitioners, researchers, and planners seeking to assess the co-benefits of NBS and integrate them into economic assessments. The results show that when considering flood risk reduction alone, all considered measures have higher costs than the benefits derived from avoiding flood damage. However, when incorporating co-benefits, several NBS have a net positive economic impact, including afforestation/reforestation and retention ponds with cost-benefit ratios of 3.5 and 5.6 respectively. This suggests that incorporating co-benefits into economic assessments can significantly increase the overall economic efficiency and viability of NBS.


Subject(s)
Floods , Risk Management , Cost-Benefit Analysis , Urbanization , Climate Change
2.
Environ Res ; 237(Pt 1): 116914, 2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37597824

ABSTRACT

To investigate the influence of high-pressure and shear effects introduced by a concentrated oxygen supply system on the membrane filtration performance, a laboratory-scale membrane bioreactor (MBR) fed artificial municipal wastewater was operated continuously for 80 days in four phases equipped with different aerations systems: (P1) bubble diffusers (days 0-40), (P2) concentrated oxygen supply system, the supersaturated dissolved oxygen (SDOX) (days 41-56), (P3) bubble diffusers (days 57-74), and (P4) SDOX (days 75-80). Various sludge physical-chemical parameters, visual inspection of the membrane, and permeability evaluations were performed. Results showed that the high-pressure effects contributed to fouling of the membranes compared to the bubble diffuser aeration system. Biofouling by microorganisms appeared to be the main contributor to the cake layer when bubble diffusers were used, while fouling by organic matter seemed to be the main contributor to the cake layer when SDOX was used. Small particle size distribution (PSD) (ranging from 1 to 10 and 1-50 µm in size) fractions are a main parameter affecting the intense fouling of membranes (e.g., formation of a dense and thin cake layer). However, PSD alone cannot explain the worsened membrane fouling tendency. Therefore, it can be assumed that a combination of several factors (which certainly includes PSD) led to the severe membrane fouling caused by the high-pressure and shear.

3.
Environ Res ; 235: 116597, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37442255

ABSTRACT

Digestate is a rich source of nutrients that can be applied in agricultural fields as fertilizer or irrigation water. However, most of the research about application of digestate have focused on its agronomic properties and neglected the potential harm of the presence of contaminants of emerging concern (CECs). Aadvanced oxidation processes (AOPs) have proved to be effective for removing these compounds from drinking water, yet there are some constrains to treat wastewater and digestate mainly due to their complex matrix. In this study, the feasibility to remove different CECs from digestate using O3 and O3/H2O2 was assessed, and the general effect of the matrix in the oxidation was explained. While the lab-scale ozonation provided an ozone dose of 1.49 mg O3/mg DOC in 5 h treatment, almost all the compounds were removed at a lower ozone dose of maximum 0.48 mg O3/mg DOC; only ibuprofen required a higher dose of 1.1 mg O3/mg DOC to be oxidized. The digestate matrix slowed down the kinetic ozonation rate to approximately 1% compared to the removal rate in demineralized water. The combined treatment (O3/H2O2) showed the additional contribution of H2O2 by decreasing the ozone demand by 59-75% for all the compounds. The acute toxicity of the digestate, measured by the inhibition of Vibrio fisheries luminescence, decreased by 18.1% during 5 h ozonation, and by 34% during 5 h O3/H2O2 treatment. Despite the high ozone consumption, the ozone dose (mg O3/mg DOC) required to remove all CECs from digestate supernatant was in the range or lower than what has been reported for other (waste-)water matrix, implying that ozonation can be considered as a post-AD treatment to produce cleaner stream for agricultural purposes.


Subject(s)
Ozone , Water Pollutants, Chemical , Water Purification , Sewage , Hydrogen Peroxide , Water Pollutants, Chemical/toxicity , Water Pollutants, Chemical/analysis , Wastewater , Water , Oxidation-Reduction
4.
Water Res ; 229: 119446, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36516560

ABSTRACT

Ca. Accumulibacter was the predominant microorganism (relative FISH bio-abundance of 67 ± 5%) in a lab-scale sequential batch reactor that accomplished enhanced biological phosphorus removal (EBPR) while using glucose and acetate as the carbon sources (1:1 COD-based ratio). Both organic compounds were completely anaerobically consumed. The reactor's performance in terms of P/C ratio, phosphorous release and uptake, and overall kinetic and stoichiometric parameters were on the high end of the reported spectrum for EBPR systems (100:9.3 net mg phosphate removal per mg COD consumed when using glucose and acetate in a 1:1 ratio). The batch tests showed that, to the best of our knowledge, this is the first time a reactor enriched with Ca. Accumulibacter can putatively utilize glucose as the sole carbon source to biologically remove phosphate (COD:P (mg/mg) removal ratio of 100:6.3 when using only glucose). Thus, this research proposes that Ca. Accumulibacter directly anaerobically stored the fed glucose primarily as glycogen by utilizing the ATP provided via the hydrolysis of poly-P and secondarily as PHA by balancing its ATP utilization (glycogen generation) and formation (PHA storage). Alternative hypotheses are also discussed. The reported findings could challenge the conventional theories of glucose assimilation by Ca. Accumulibacter, and can be of significance for the biological removal of phosphorus from wastewaters with high contents of fermentable compounds or low VFAs.


Subject(s)
Bioreactors , Glucose , Glycogen/metabolism , Phosphorus/metabolism , Phosphates , Carbon/metabolism , Acetates/metabolism , Adenosine Triphosphate
5.
Membranes (Basel) ; 12(3)2022 Feb 25.
Article in English | MEDLINE | ID: mdl-35323737

ABSTRACT

This study evaluated the effects of sludge retention time (SRT) on the membrane filtration performance of an anaerobic membrane bioreactor (AnMBR) fed lipid-rich synthetic dairy wastewater. The membrane filtration performance was evaluated in two AnMBR systems operated at two different SRTs, i.e., 20 and 40 days. For the AnMBR operated at 40 days, SRT exhibited worse membrane filtration performance characterized by operational transmembrane pressures (TMP) exceeding the maximum allowed value and high total resistances to filtration (Rtotal). The sludge in the two reactors evaluated at the different SRTs showed similar sludge filterability properties. However, the sludge in the reactor operated at 40 days SRT was characterized by exhibiting the highest concentrations of: (i) total suspended solids (TSS), (ii) small-sized particles, (iii) extracellular polymeric substances (EPS), (iv) soluble microbial products (SMP), (v) fats, oils and grease (FOG), and (vi) long-chain fatty acids (LCFA). The cake layer resistance was the major contributor to the overall resistance to filtration. The high TSS concentration observed in the AnMBR systems apparently contributed to a less permeable cake layer introducing a negative effect on the membrane filtration performance.

6.
Sci Total Environ ; 828: 154142, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35227715

ABSTRACT

Thermal drying is an effective sludge treatment method for dealing with large volumes of sludge. Microwave (MW) technology has been proposed as an effective and efficient technology for sludge drying. The physical-chemical properties of the sludge depend both on the origin of the sludge, as well as on the treatment process at which the sludge has been exposed. The physical-chemical properties of the sludge affect the performance and the subsequent valorisation and management of the sludge. This study evaluated the effect of certain physical-chemical properties of the sludge (moisture content, organic content, calorific value, porosity, hydrophobicity, and water-sludge molecular interaction, among others) on the MW sludge drying and energy performance. Four different types of sludge were evaluated collected from municipal wastewater treatment plants and septic tanks. The performance of the MW system was assessed by evaluating the sludge drying rates, exposure times, energy efficiencies and power input consumed by the MW system and linking the MW drying performance to the sludge physical-chemical properties. The results confirmed that MW drying substantially extends the constant drying period associated with unbound water evaporation, irrespective of the sludge sample evaluated. However, the duration and intensity were determined to depend on the dielectric properties of the sludge, particularly on the distribution of bound and free water. Sludge samples with a higher amount of free and loosely bound water absorbed and converted MW energy into heat more efficiently than sludge samples with a lower amount of free water. As a result, the sludge drying rates increased and the constant drying rate period prolonged; hence, leading to an increase in MW drying energy efficiency. The availability of free and loosely bound water molecules was favoured when hydrophobic compounds, e.g., oils and fats, were present in the sludge.


Subject(s)
Microwaves , Sewage , Desiccation/methods , Oils , Sewage/chemistry , Water
7.
Environ Sci Pollut Res Int ; 29(28): 42016-42036, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34718952

ABSTRACT

The provision of effective sanitation strategies has a significant impact on public health. However, the treatment of septic sludge still presents some challenges worldwide. Consequently, innovative technologies capable of an effective and efficient sludge treatment, mostly at a decentralized level, are in high demand to improve sanitation provision. To address this problem, this study evaluates a novel semi-decentralised mobile faecal sludge treatment system, the pilot-system for which consists of a combination of several individual processes including mechanical dewatering (MD), microwave (MW) drying, and membrane filtration (ultrafiltration [UF] and reverse osmosis [RO]). The system evaluation was carried out by treating raw, partially digested faecal sludge (FS) from septic tanks-hence, septic sludge (SS)-in the Jordan Valley, Jordan. The pilot-scale system exhibited an effective and flexible treatment performance for (i) sanitizing faecal sludge and related liquid streams (MW and UF); (ii) reducing the treated sludge mass (and sludge volume) (MD and MW); and (iii) producing a high-quality treated liquid stream ideal for water reclamation applications (UF and RO). The MD process removed approximately 99% of the initial SS water content. The MW drying system completely removed E. coli and dehydrated the dewatered sludge at low energy expenditures of 0.75 MJ kg-1 and 5.5 MJ kg-1, respectively. Such energy expenditures can be further reduced by approximately 40% by recovering energy in the condensate and burning the dried sludge, which can then be reused inland applications. The membrane filtration system (UF and RO) was able to produce high-quality treated water that is ideal for the water reuse applications that irrigation requires, as well as meeting the Jordanian standard 893/2006. In addition, the system can also be powered by renewable energy sources, such as photovoltaic energy. Therefore, this research demonstrates that the evaluated semi-decentralised mobile system is technically feasible for the in situ treatment of SS (sanitization and dehydration), while also being effective for simultaneously recovering valuable resources, such as energy, water, and nutrients.


Subject(s)
Escherichia coli , Sewage , Dehydration , Humans , Jordan , Waste Disposal, Fluid , Water
8.
Article in English | MEDLINE | ID: mdl-33803152

ABSTRACT

In Khulna, Bangladesh, mechanical faecal sludge (FS) emptying and transport (E&T) service is provided by community development committees (CDCs) and the Khulna City Corporation (KCC). Without considering capital expenditure and depreciation, financial analysis for one year revealed that a CDC-1 m3 vacutug made a profit of Bangladeshi taka (BDT) 145,780 (USD $1746) whereas a KCC-2 m3 vacutug was in the loss of BDT 218,179 (USD $2613). There is a need to engage the private sector for sustainable service provision. Some of the key elements of enabling the environment for private sector engagement are policy/strategy, institutional and regulatory framework, implementation capacity, and financial viability. Existing policy/strategy/frameworks acknowledged the need and suggested plans for private sector engagement, and decentralised authority to city corporations. With increasing private-public partnership projects and collaboration in the sanitation sector, capacity of the KCC and the private sector are increasing. Financial viability of the FS E&T business is primarily dependent on the number of trips and the emptying fee. For the E&T business to be financially viable, a 2 m3 vacutug should make six trips/day (internal rate of return (IRR)-13%, discount rate-6.5%) with an emptying fee of BDT 750 (USD $9)/m3. Despite the lack of operative guidelines for faecal sludge management (FSM), enabling the environment for private sector engagement in FS E&T business in Khulna seems favourable.


Subject(s)
Private Sector , Sewage , Bangladesh , Cities , Sanitation
9.
Water Res ; 195: 116992, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33714012

ABSTRACT

The aerobic granular sludge (AGS) process is an effective wastewater treatment technology for organic matter and nutrient removal that has been introduced in the market rapidly. Until now, limited information is available on AGS regarding the removal of bacterial and viral pathogenic organisms present in sewage. This study focussed on determining the relation between reactor operational conditions (plug flow feeding, turbulent aeration and settling) and physical and biological mechanisms on removing two faecal surrogates, Escherichia coli and MS2 bacteriophages. Two AGS laboratory-scale systems were separately fed with influent spiked with 1.0 × 106 CFU/100 mL of E. coli and 1.3 × 108 PFU/100 mL of MS2 bacteriophages and followed during the different operational phases. The reactors contained only granular sludge and no flocculent sludge. Both systems showed reductions in the liquid phase of 0.3 Log10 during anaerobic feeding caused by a dilution factor and attachment of the organisms on the granules. Higher removal efficiencies were achieved during aeration, approximately 1 Log10 for E. coli and 0.6 Log10 for the MS2 bacteriophages caused mainly by predation. The 18S sequencing analysis revealed high operational taxonomic units (OTUs) of free-living protozoa genera Rhogostoma and Telotrochidium concerning the whole eukaryotic community. Attached ciliates propagated after the addition of the E. coli, an active contribution of the genera Epistylis, Vorticella, and Pseudovorticella was found when the reactor reached stability. In contrast, no significant growth of predators occurred when spiking the system with MS2 bacteriophages, indicating a low contribution of protozoa on the phage removal. Settling did not contribute to the removal of the studied bacterial and viral surrogates.


Subject(s)
Sewage , Water Purification , Aerobiosis , Bioreactors , Escherichia coli , Waste Disposal, Fluid
10.
Sci Total Environ ; 771: 144847, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-33548701

ABSTRACT

Conventional diffused aeration systems (such as fine-bubble diffusers) exhibit a poor oxygen transfer in wastewater treatment plants (WWTPs), particularly when operating at sludge concentrations higher than 15 g L-1. The supersaturated dissolved oxygen (SDOX) system has been proposed as an alternative for supplying dissolved oxygen (DO) at high mixed liquor suspended solids (MLSS) concentrations. The advantages introduced by such technology include the possibility of operating WWTPs at much higher than usual MLSS concentrations, increasing the treatment capacity of WWTPs. Recent studies have demonstrated that the SDOX system has higher oxygen transfer rates (OTRs) and oxygen transfer efficiencies (OTEs) relative to fine-bubble diffusers. However, it is unknown if the high-pressure conditions introduced by SDOX may possibly impact the biological performance of WWTPs. In this study, the effects of SDOX technology on the biological performance of a membrane bioreactor (MBR) were evaluated. The MBR was operated at an MLSS concentration of approximately 15 g L-1 in four phases as follows: (P1) with bubble diffusers, (P2) with an SDOX unit, (P3) with the bubble diffusers, and (P4) with the SDOX unit. The performance of the MBR was assessed by monitoring the sludge concentration, as well as changes in the particle size distribution (PSD), sludge activity, organic matter removal and nitrification performance, and changes in the microbial community within the MBR. The operational conditions exerted by the SDOX technology did not affect the concentration of active biomass during the study period. The biological performance of the MBR was not affected by the introduction of the SDOX technology. Finally, the microbial community was relatively stable although some variations at the family and genus level were evident during each of the study phases. Therefore, the SDOX system can be proposed as an alternative technology for DO supply in WWTPs increasing the overall treatment capacity.


Subject(s)
Oxygen , Waste Disposal, Fluid , Bioreactors , Membranes, Artificial , Population Dynamics , Sewage
11.
Chemosphere ; 272: 129899, 2021 Jun.
Article in English | MEDLINE | ID: mdl-35534969

ABSTRACT

The use of near-infrared (NIR) spectroscopy in wastewater treatment has continuously expanded. As an alternative to conventional analytical methods for monitoring constituents in wastewater treatment processes, the use of NIR spectroscopy is considered to be cost-effective and less time-consuming. NIR spectroscopy does not distort the measured sample in any way as no prior treatment is required, making it a waste-free technique. On the negative side, one has to be very well versed with chemometric techniques to interpret the results. In this study, filtered and centrifuged wastewater and sludge samples from a lab-scale membrane bioreactor (MBR) were analysed. Two analytical methods (conventional and NIR spectroscopy) were used to determine and compare major wastewater constituents. Particular attention was paid to soluble microbial products (SMPs) and extracellular polymeric substances (EPSs) known to promote membrane fouling. The parameters measured by NIR spectroscopy were analysed and processed with partial least squares regression (PLSR) and artificial neural networks (ANN) models to assess whether the evaluated wastewater constituents can be monitored by NIR spectroscopy. Very good results were obtained with PLSR models, except for the determination of SMP, making the model qualitative rather than quantitative for their monitoring. ANN showed better performance in terms of correlation of NIR spectra with all measured parameters, resulting in correlation coefficients higher than 0.97 for training, testing, and validation in most cases. Based on the results of this research, the combination of NIR spectra and chemometric modelling offers advantages over conventional analytical methods.


Subject(s)
Spectroscopy, Near-Infrared , Wastewater , Bioreactors , Membranes, Artificial , Sewage/chemistry , Spectroscopy, Near-Infrared/methods , Wastewater/chemistry
12.
Environ Technol ; 42(4): 597-608, 2021 Jan.
Article in English | MEDLINE | ID: mdl-31264939

ABSTRACT

In this study, the impact of applied solids retention time (SRT) on the biological performance of an anaerobic membrane bioreactor (AnMBR) treating synthetic dairy wastewater with high lipid content was assessed. Two side-stream AnMBR systems were operated at an SRT of 20 and 40 days (R20 and R40, respectively), equipped with an inside-out tubular membrane operated in cross-flow mode under full-scale operational conditions, i.e. crossflow velocity, transmembrane pressure, membrane flux. Successful operation was achieved and removal efficiencies of both reactors were up to 99% applying an organic loading rate (OLR) of 4.7 g COD L-1 d-1. No precipitation of lipids was observed throughout the operational period, keeping the lipids available for the anaerobic degradation. Long chain fatty acid (LCFA) accumulation was very modest and amounted 148 and 115 mg LCFA-COD per gram of volatile suspended solids (VSS) for R20 and R40, respectively. At an SRT of 40 days, a slightly better biological conversion was obtained. Periodically performed specific methanogenic activity (SMA) tests showed stabilization of the SMA for R40 sludge, whereas for R20 sludge the SMA continued to decrease. This study revealed a more stable reactor performance operating the AnMBR at an SRT of 40 days compared to 20 days.


Subject(s)
Waste Disposal, Fluid , Wastewater , Anaerobiosis , Bioreactors , Membrane Lipids , Methane , Sewage
13.
Water Sci Technol ; 82(11): 2220-2233, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33339779

ABSTRACT

A majority of the world's population use onsite sanitation systems, which store or treat excreta close to where it is generated. Sludge from these systems needs to be managed through a series of stages, known as the sanitation value chain. There is a huge diversity of service providers, not only within each part of the chain, but also along the chain bridging the different components. These service providers are linked not only by the flow of materials, but also by the transfer of money. Therefore for this system to be considered financially sustainable all services from the toilet to reuse or disposal need to be considered. A tool has been developed (eSOSView™) to simulate, evaluate, and optimise the financial flows along and within the sanitation value chain. In this paper eSOSView™ was tested, validated (using existing data), and piloted (including data collection). This paper demonstrates how eSOSView ™ can be used to evaluate different financial flow models, to assess financial sustainability in different parts of the sanitation value chain and optimise the financial sustainability along the sanitation value chain.


Subject(s)
Sanitation , Sewage
14.
Sci Total Environ ; 741: 140480, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-32886969

ABSTRACT

The co-treatment of two synthetic faecal sludges (FS-1 and FS-2) with municipal synthetic wastewater (WW) was evaluated in an aerobic granular sludge (AGS) reactor. After characterisation, FS-1 showed the following concentrations, representative for medium-strength FS: 12,180 mg TSS L-1, 24,300 mg total COD L-1, 93.8 mg PO3-P L-1, and 325 mg NH4-N L-1. The NO3-N concentration was relatively high (300 mg L-1). For FS-2, the main difference with FS-1 was a lower nitrate concentration (18 mg L-1). The recipes were added consecutively, together with the WW, to an AGS reactor. In the case of FS-1, the system was fed with 7.2 kg total COD m-3d-1 and 0.5 kg Nitrogen m-3d-1. Undesired denitrification occurred during feeding and settling resulting in floating sludge and wash-out. In the case of FS-2, the system was fed with 8.0 kg total COD m-3d-1 and 0.3 kg Nitrogen m-3d-1. The lower NO3-N concentration in FS-2 resulted in less floating sludge, a more stabilised granular bed and better effluent concentrations. To enhance the hydrolysis of the slowly biodegradable particulates from the synthetic FS, an anaerobic stand-by period was added and the aeration period was increased. Overall, when compared to a control AGS reactor, a lower COD consumption (from 87 to 35 mg g-1 VSS h-1), P-uptake rates (from 6.0 to 2.0 mg P g VSS-1 h-1) and NH4-N removal (from 2.5 to 1.4 mg NH4-N g VSS-1 h-1) were registered after introducing the synthetic FS. Approximately 40% of the granular bed became flocculent at the end of the study, and a reduction of the granular size accompanied by higher solids accumulation in the reactor was observed. A considerable protozoa Vorticella spp. bloom attached to the granules and the accumulated particles occurred; potentially contributing to the removal of the suspended solids which were part of the FS recipe.


Subject(s)
Sewage , Wastewater , Bioreactors , Nitrogen , Waste Disposal, Fluid
15.
Article in English | MEDLINE | ID: mdl-32882804

ABSTRACT

Sanitation infrastructure are not able to cope with the increasing population in low-income countries, which leaves populations exposed to faecal contamination from multiple pathways. This study evaluated public health risk (using SaniPath) in a low-income community during the dry season, to identify the dominant exposure pathways, and compare this data to existing data for the rainy season, questioning the assumption that risk of faecal contamination is higher in the rainy season. SaniPath was used to collect and assess exposure and environmental data, and to generate risk profiles for each pathway. In the dry season the highest exposure frequency was for bathing and street food, exposure frequency generally increased, and seasonal variation was found in five pathways. The highest hazards in the dry season were through contact with drains, soil, and street food. Seasonal variation was found in the contamination of open drains and street food, with higher levels of Escherichia coli (E. coli) in the dry season. Open drains were identified as the most dominant risk pathway in both seasons, but risk was higher in the dry season. This highlights the complex nature of seasonal variation of faecal risk, and questions the assumption that risk is higher in the rainy season.


Subject(s)
Escherichia coli , Feces , Poverty , Sanitation , Humans , Seasons , Uganda/epidemiology
16.
Sci Total Environ ; 742: 140541, 2020 Nov 10.
Article in English | MEDLINE | ID: mdl-32629261

ABSTRACT

Sewage sludge management and treatment can represent up to approximately 30% of the overall operational costs of a wastewater treatment plant. Microwave (MW) drying has been recognized as a feasible technology for sludge treatment. However, MW drying systems exhibit high energy expenditures due to: (i) unnecessary heating of the cavity and other components of the system, (ii) ineffective extraction of the condensate from the irradiation cavity, and (iii) an inefficient use of the microwave energy, among others issues. This study investigated the performance of a novel pilot-scale MW system for sludge drying, specifically designed addressing the shortcomings previously described. The performance of the system was assessed drying municipal centrifuged wasted activated sludge at MW output powers from 1 to 6 kW and evaluating the system's drying rates and exposure times, specific energy outputs, MW generation efficiencies, overall energy efficiencies, and specific energy consumption. The results indicated that MW drying significantly extends the duration of the constant rate drying period associated with the evaporation of the unbound sludge water, a phase associated with low energy input requirement for evaporating water. Moreover, the higher the MW output power, the higher the sludge power absorption density, and the MW generation efficiency. MW generation efficiencies of up to 70% were reported. The higher the power absorption density, the lower the chances for energy losses in the form of reflected power and/or energy dissipated into the MW system. Specific energy consumptions as low as 2.6 MJ L-1 (0.74 kWh L-1) could be achieved, well in the range of conventional thermal dryers. The results obtained in this research provide sufficient evidence to conclude that the modifications introduced to the novel pilot-scale MW system mitigated the shortcomings of existing MW systems, and that the technology has great potential to effectively and efficiently drying municipal sewage sludge.

17.
Nat Biomed Eng ; 4(6): 581-582, 2020 06.
Article in English | MEDLINE | ID: mdl-32533122
18.
Water Res X ; 6: 100040, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-31909394

ABSTRACT

The aim of this study was to evaluate the effectiveness of the novel aerobic granular sludge (AGS) wastewater treatment technology in removing faecal indicator organisms (FIOs) compared to the conventional activated sludge (CAS) treatment system. The work was carried out at two full-scale wastewater treatment plants (WWTP) in the Netherlands, Vroomshoop and Garmerwolde. Both treatment plants have a CAS and AGS system operated in parallel. The parallel treatment lines are provided with the same influent wastewater. The concentrations of the measured FIOs in the influent of the two WWTPs were comparable with reported literature values as follows: F-specific RNA bacteriophages at 106 PFU/100 mL, and Escherichia coli (E. coli), Enterococci, and Thermotolerant coliforms (TtC) at 105 to 106 CFU/100 mL. Although both systems (CAS and AGS) are different in terms of design, operation, and microbial community, both systems showed similar FIOs removal efficiency. At the Vroomshoop WWTP, Log10 removals for F-specific RNA bacteriophages of 1.4 ± 0.5 and 1.3 ± 0.6 were obtained for the AGS and CAS systems, while at the Garmerwolde WWTP, Log10 removals for F-specific RNA bacteriophages of 1.9 ± 0.7 and 2.1 ± 0.7 were found for the AGS and CAS systems. Correspondingly, E. coli, Enterococci, and TtC Log10 removals of 1.7 ± 0.7 and 1.1 ± 0.7 were achieved for the AGS and CAS systems at Vroomshoop WWTP. For Garmerwolde WWTP Log10 removals of 2.3 ± 0.8 and 1.9 ± 0.7 for the AGS and CAS systems were found, respectively. The measured difference in removal rates between the plants was not significant. Physicochemical water quality parameters, such as the concentrations of organic matter, nutrients, and total suspended solids (TSS) were also determined. Overall, it was not possible to establish a direct correlation between the physicochemical parameters and the removal of FIOs for any of the treatment systems (CAS and AGS). Only the removal of TSS could be positively correlated to the E. coli removal for the AGS technology at the evaluated WWTPs.

19.
Sci Total Environ ; 704: 135456, 2020 Feb 20.
Article in English | MEDLINE | ID: mdl-31837866

ABSTRACT

The high frequency and intensity of urban floods caused by climate change, urbanisation and infrastructure failures increase public health risks when the flood water contaminated from combined sewer overflows (CSOs) or other sources of faecal contamination remains on urban surfaces. This study contributes to a better understanding of the effects of urban and recreational surfaces on the occurrence of waterborne pathogens. The inactivation of selected indicator organisms was studied under controlled exposure to artificial sunlight for 6 h followed by 18 h in dark conditions. Concrete, asphalt, pavement blocks and glass as control were inoculated with artificial floodwater containing, as indicator organisms, Escherichia coli bacteria, which are common faecal indicator bacteria (FIB) for water quality assessment, Bacillus subtilis spores chosen as surrogates for Cryptosporidium parvum oocysts and Giardia cysts, and bacteriophages MS2 as indicators for viral contamination. On practically all the surfaces in this study, E. coli had the highest inactivation under light conditions followed by MS2 and B. subtilis, except asphalt where MS2 was inactivated faster. The highest inactivation under light conditions was seen with E. coli on a concrete surface (pH 9.6) with an inactivation rate of 1.85 h-1. However, the pH of the surfaces (varying between 7.0 and 9.6) did not have any influence on inactivation rates under dark conditions. MS2 bacteriophage had the highest inactivation under light conditions on asphalt with a rate of 1.29 h-1. No die-off of B. subtilis spores was observed on any of the surfaces during the experiment, neither in light nor in dark conditions. This study underpins the need to use different indicator organisms to test their inactivation after flooding. It also suggests that given the sunlight conditions, concentration of indicator organisms and type of surface, the fate of waterborne pathogens after a flood could be estimated.


Subject(s)
Environmental Monitoring/methods , Floods , Water Microbiology , Bacteria , Cities , Cryptosporidiosis , Cryptosporidium , Cryptosporidium parvum , Levivirus , Oocysts
20.
J Environ Manage ; 250: 109516, 2019 Nov 15.
Article in English | MEDLINE | ID: mdl-31513998

ABSTRACT

A better understanding of the effects of different urban and recreational surfaces on the die-off of water-borne pathogens that can cause infections after urban floods if released from surcharged combined sewers and other sources of fecal contamination is needed. The die-off of fecal indicator Escherichia coli was studied under controlled exposure to simulated sunlight on a range of different surfaces found in urban environments: gravel, sand, asphalt, pavement blocks, concrete, playground rubber tiles and grass, using glass as control. The surfaces were inoculated with artificial flooding water containing 105 colony forming units (CFU) of E. coli per mL and sampled periodically using the sterile cotton swab technique, after lowering the water level. The results show that dark inactivation was not statistically significant for any surface, suggesting that chemical composition and pH (varying between 6.5 ±â€¯0.8 and 9.2 ±â€¯0.4) did not affect the die-off rates. The highest light-induced die-off rates for E. coli after the floodwater recession, observed on rubber (>3.46 h-1) and asphalt (2.7 h-1), were attributed to temperature stress and loss of surface moisture.


Subject(s)
Escherichia coli , Floods , Feces , Fresh Water , Water Microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...